• 1 909 418 2149

Building

• 624,627 SF (2,670 SF mezzanine)

Office

• 5,861 SF of 2-story office space

Clear Height

• 36’ clear (inside 1st column line from docks)

Columns

• 56’-0” by 50’-0” typical column spacing (60’ spacing in speed bay)

Parking

• 160 trailer stalls and 247 auto stalls

Construction

• Concrete tilt-up walls, steel truss and girder roof structure with a panelized wood deck

Doors

• 137 dock high doors (9’ x 10’)
• 2 grade level doors (12’ x 15’)

Fire Protection

• ESFR–K25

Paving

• 100% concrete paving: 6” thick, 3000 psi concrete at truck yard and drive aisles, and 5” thick at auto parking

Roofing

• Class “A”, 4-ply asphaltic built-up roof system with fifteen (15) year, no dollar limit warranty

Roof Structure

• Metal truss hybrid

Insulation

• White scrim foil

Glazing

• At SW office: 1” insulated with outer lite as ¼” medium performance reflective glass and inner lite as ¼” clear glass
• Elsewhere: ¼” thick, medium performance reflective glass

Skylights

• 3% skylights

Warehouse Slab

• 7” thick 4,000 psi concrete with dowel baskets at all control joints
• MM80 throughout speedbays
• Seal concrete floors with one (1) coat of water based sealer, Lapidolith or equal
• Slab to have minimum flatness of FF-50 and levelness of FL-30, leveled with laser screed
• Vapor barrier is 15 mil plastic Stegowrap at two office areas

Utilities

• Sewer service at building corners
• Domestic water service to office locations
• Irrigation water service with backflow preventer
• Telephone service conduits to the electrical room

Fencing

• Concrete tilt-up screen walls with motorized tube steel gates
• Wrought iron and tube steel fence

Painting

• Exterior concrete walls: one (1) coat of primer and one (1) finish coat paint to cover
• Interior concrete walls: one (1) coat of flat paint to cover
• Elastomeric paint at top and inside of parapet wall
• All exterior hollow metal doors and dock doors: one (1) coat exterior primer and two (2) coats latex paint

Landscaping

• Drought tolerant landscaping to be used where possible, automatic sprinklers

Electrical

• 4000 amp pull section (UGPS) with 800 amp service

Ventilation

• Louvered skylights and wall louvers